Mount Airy · PhiladelphiaLicensed & insured · Phila. L&IResidential & light commercial

A house is only as good as its worst connection.

  • We find it, we draw it, we fix it properly. 120/240 V · 60 Hz · live
  • Stone twins, Victorians, knob-and-tube. Mount Airy since 2011
  • Every circuit traced, tested and labelled. 0 callbacks in 2026
  • Drawings handed over, not in someone's head. as-built · rev A
follow the current
SERVICE 120/240 V · 1Ø · 60 Hz WAVEFORM live · L1 + L2

01 — THE STREET

Your power arrives long before it arrives well.

Between the pole transformer on your block and your kitchen there are six places where a bad connection becomes your problem. We start at the service and work inward, because fixing an outlet that sits on a failing service is decoration.

120/240 Vsingle phase, three wire — measured at the lugs, not assumed
SERVICE DROP · OVERHEAD

02 — THE METER

Everything you pay for passes through one point.

A service entrance conductor running warm is the cheapest catastrophe in the building. We check the terminations, the seal and the grounding electrode before we quote anything else, and we tell you what we found in writing.

60 Awhat we still find behind Mount Airy stone twins — usually the real ceiling
kWh REVENUE METER · SEALED

03 — THE PANEL

This is where good electricians are separated from cheap ones.

Straight runs, torqued terminations, a printed schedule, spare ways left on purpose. A panel is the only part of our work you will still be reading in fifteen years — so we build it to be read.

8ways typical · every one traced and labelled
LOAD CENTRE · SCHEDULE ATTACHED

04 — THE CIRCUIT

A cable is sized for the worst day, not an average one.

Load, length, grouping, ambient temperature, the voltage drop at the far end. We calculate it, we write it down, and we leave the calculation with you — which is why nothing we install gets warm.

2.5 %maximum voltage drop we design to
12 AWG NM-B · 60 FT RUN

05 — THE ROOM

And then it is just a room that works.

Switches where your hand goes. Sockets where the furniture actually sits. Light that flatters the room instead of flooding it. The engineering disappears, which is the entire point of doing it properly.

0callbacks on installations completed in 2026
FINISHED · TESTED · SIGNED OFF

What we take on

eight services · every job leaves with a drawing

Now the part most electricians skip.

We design it before we install it. Set your house up below and the diagram solves a real load calculation — the same arithmetic we'd do on site. It will tell you honestly whether the work is inside your panel or out at the street.

SINGLE-LINE DIAGRAM — YOUR HOUSE

rev A · solving
UTILITY SUPPLY 120/240 V · 1Ø · 60 Hz kWh METER MAIN 100 A BUSBAR
LOADS PRESENT
CONNECTED LOAD
0VA
CALCULATED DEMAND
0.0A
CIRCUITS
0ways
SPARE CAPACITY
0%
0 A100 A service

Solving.

Estimate only — NEC Article 220 standard calculation. General lighting at 3 VA/ft² (220.12), small-appliance and laundry branch circuits (220.52), first 3,000 VA at 100% and the remainder at 35% (220.42), range per 220.55, EV at 100% with no diversity (625.42). A site visit, a look inside your panel and a Philadelphia L&I permit confirm the real number.

Panel schedule

generated from the diagram above · this is what you'd receive

WAYCIRCUITCONDUCTOR BREAKERLOAD

What you're left holding

after we've packed up

Drawings
0%

Every job leaves with an as-built single-line diagram and a printed panel schedule. Hand it to the next electrician and they'll know exactly what they're looking at.

Photographs
0

Images filed per job — every wall photographed before it closes, so nobody has to guess where a cable runs.

Callbacks
0

On installations completed in 2026. We'd rather spend the day calculating than spend a Saturday coming back.

Send us the one nobody else wants to quote.

A survey, a load calculation and a fixed price before anyone touches a wall. If your service is the problem we'll tell you that first, even when it costs us the job.

Call
(267) 334-2069
Email
[email protected]
Service area
Philadelphia